Hello Sign in 0
Popular: power drill led strip rc car smart watch scooter tool set

DSO2C10 Digital Oscilloscope 2CH Digital Storage 1GS/s Sampling Rate 100MHz Bandwidth Dual Channel Economical Oscilloscope

$1,559.92
Out of Stock

Description


Features:


1), 2 channels, each channel has independent knob control;

2), Analog bandwidth 100MHZ

3) The highest sampling rate is 1 GSa/s;

4), The storage depth is 8Mpts;

5), The vertical range of 2mV/div ~ 10V/div;

6) Vertical resolution: 8bit;

7) Trigger: edge, pulse, video, slope, timeout, window, pattern, interval, runt, UART, LIN, CAN, SPI, IIC;

8) Bus decoding and protocol analysis: RS232/UART, I2C, SPI, CAN, LIN;

9), Can save settings, waveforms, reference waveforms, CSV, pictures and other data formats.

10), 3-digit digital voltmeter and 6-digit frequency meter functions;

11) Support 32 kinds of automatic measurement and statistics functions, real-time statistics of minimum, maximum, standard deviation and other statistical information;

12), Two groups of digital voltmeter functions;

13) Support threshold test to realize free measurement in the screen;

14), Rich SCPI remote control instructions;

15). Provide multiple types of peripheral interfaces: USB Host/Device.


Product Model(NOTE:Click on the model to reach the purchase link of the corresponding model):


Model

          Channels

Bandwidth
Sampling Rate
Storage Depth
Signal Source (AWG)

>>DSO2C10<<

2CH

100MHz

1GSa/S 8M /

>>DSO2C15<<

2CH 150MHz 1GSa/S
8M
/

>>DSO2D10<<

2CH+1CH 100MHz 1GSa/S
8M
1CH

>>DSO2D15<<

2CH+1CH
150MHz 1GSa/S
8M
1CH


>>Please Click Here to Download the English User Manual<<


>>Click to Download DSO2000 Software<<


Specification:



model DSO2D15 DSO2D10 DSO2C15 DSO2C10
bandwidth 150MHz 100MHz 150MHz 100MHz
Number of oscilloscope channels 2CH 2CH 2CH 2CH
Built-in signal source 1CH 1CH  -  -
Oscilloscope index
Sampling rate range 1GSa/s (single channel), 500MSa/s (dual channel)
Collection method
sampling Sample data
Peak-to-peak Display high frequency and random glitches
average value Average waveform, times: 4, 8, 16, 32, 64, 128
High precision Up to 12bit
enter
Input coupling DC, AC or ground (DC, AC, GND)
input resistance 1MΩ±2% ‖20pF±3pF
Probe attenuation coefficient setting 1X, 10X, 100X, 1000X
Voltage level 300V CAT II
Maximum input voltage 300VRMS (10X)
Horizontal system
Waveform interpolation (sin x)/x
Maximum record length Maximum 8M per channel
Maximum 4M for dual channels
Horizontal scale range 2ns/div~100s/div 1, 2, 5 steps
Time base mode YT, XY, Roll 
Zero offsets ±0.5 div×minimum time base gear
Sampling rate and delay time accuracy ±50ppm
Clock drift ≤±5 ppm/year
Incremental time measurement accuracy Single, "sampled" mode
(Full bandwidth) ±(1 sampling interval+100ppm×reading+0.6ns)
>16 times above average
±(1 sampling interval+100ppm×reading+0.4ns)
Sampling interval = second/div÷200
Vertical system
model DSO2D15 DSO2D10 DSO2C15 DSO2C10
bandwidth 150MHz 100MHz 150MHz 100MHz
Rise time at BNC (typical) 2.3ns 3.5ns 2.3ns 3.5ns
Vertical resolution 8-bit resolution, simultaneous sampling for each channel
Vertical sensitivity 2mV/div to 10V/div
Offsets range 2mV/div to 20mV/div, ±100mV; 50mV/div to 200mV/div, ±1V;
500mV / div to 2V / cell, ± 10V; 5V / div to 10V / division, ± 50V
computation Add, subtract, multiply, divide, FFT
FFT Window: Rectangular, Hanning, Hamming, Brackman, Bartlett, flat top window
Bandwidth limit 20MHz
Low frequency response (-3db) ≤10Hz at BNC
Vertical gain accuracy In the "sample" or "average" acquisition mode, the accuracy of 10V/div to 10mV/div is ±3%;
In "Sampling" or "Average" acquisition mode, the accuracy of 5mV/div to 2mV/div is ±4%
DC offsets accuracy ±0.1 div±2 mV±1% offsets value
Voltage measurement repeatability, average acquisition mode Under the same settings and environmental conditions, the voltage increment between any two sets of average values ​​of more than 16 waveforms: ±(3%×reading+0.05 division)
Note: The bandwidth is reduced to 6MHz when using X1 probe