{"product_id":"esr02pro-digital-transistor-smd-components-tester-diode-triode-capacitance-inductance-meter","title":"ESR02PRO Digital Transistor SMD Components Tester Diode Triode Capacitance Inductance Meter","description":"\u003cdiv id=\"specification\"\u003e\u003c\/div\u003e\u003cdiv id=\"specification_end\"\u003e\u003c\/div\u003e\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003eThe instrument is a small electronic enthusiasts, developers, electronic maintenance and production plant research and development of small instruments. Can be measured in-line devices, but also test chip devices, can be measured a variety of diodes, transistors, \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003eMOS tube; can determine the device type, the polarity of the pin, the output HFE, valve voltage, the junction capacitance of the FET, measurable capacitance and resistance.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e1. Two key operation, automatic shutdown.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e2. A key operation, boot test, a key to get.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e3. Automatically test the pin element and display them on the LCD.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e4.1602 LCD screen with LCD (12864 LCD backlight).\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e5. Test speed, active ingredient test: 2 seconds (in addition to the larger capacitor capacitance measurement also takes a long time, the measurement time is one minute is normal).\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e6. Only 20na off current.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e7. Automatic detection of \u003cstrong\u003eNPN, PNP bipolar transistors, N-channel and P-channel MOS field-effect transistors, junction type FET, diodes, diodes, thyristors, low power unidirectional and bidirectional thyristors\u003c\/strong\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e8. Automatic identification element pin arrangement.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e9. Bipolar transistor current amplification factor and base-emitter threshold voltage measurement.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e10. Identify the Darlington transistor by the base emitter threshold voltage and the high current amplification factor.\u003c\/span\u003e\u003cbr\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e11. Detectable bipolar transistors and MOS transistor protection diodes.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e12. Gate MOS FET threshold voltage and gate capacitance measurement.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e13. Two resistors and resistor symbols can be measured simultaneously. The right shows a decimal value of 4. Both sides of the resistor symbol show the number of pins. So you can measure the potentiometer. If the potentiometer wiper does not move to extreme positions, we can distinguish between the middle and the ends of the needle.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e14. Resistive measurement resolution of 0.1Ω, can measure 50MΩ.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e15. Can measure 325pf-100mf capacitor, resolution 1pf.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e16. 2uf More capacitors can measure the equivalent series resistance at the same time. Two can be displayed in decimal values with a resolution of 0.01Ω.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e17. Two diodes can be displayed in the correct order and the diode symbol, and the diode forward voltage is given.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e18. The LED is detected as a diode with a higher forward voltage. The combination of LEDs is identified as two diodes.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e19. Reverse breakdown voltage less than 4.5v zener diode can be identified.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e20. Can measure a single diode reverse capacitance. If the bipolar transistor is connected to the collector and emitter of the base and pin, the collector or emitter junction reverse capacitance can be measured.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e21. Can be connected with a single measurement rectifier bridge.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003eResistance: \u003cspan style=\"color:#ff0000;\"\u003e\u003cstrong\u003e0Ω-50MΩ \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\tResolution: 0.01Ω\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003eCapacitance: \u003cspan style=\"color:#ff0000;\"\u003e\u003cstrong\u003e25pf-100mf \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\tResolution: 1pf\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003eInductance: \u003cspan style=\"color:#ff0000;\"\u003e\u003cstrong\u003e0.01mH-20H \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\tResolution: 0.01mH\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003eMeasurement capacitance ESR Resolution: 0.01Ω\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003eBattery: 9V battery (\u003cstrong\u003eNot included\u003c\/strong\u003e)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cbr\u003e\n\t\u003cdiv style=\"text-align: center;\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv style=\"text-align: center;\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv style=\"text-align: center;\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv style=\"text-align: center;\"\u003e\n\t\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eInstructions:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e1. Press the \"boot \/ test\" can be achieved boot and a test function, multiple tests can be repeated by this key; measured after 20 seconds, no operation automatically shut down.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e2. The instrument provides patch, plug-in and external table three measurement methods, each way 1,2,3 feet are the same correspondence.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e3. The device does not need to distinguish between the order of discipline, the measurement will be completed after the completion of each pin corresponding to the device function.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e4. The instrument printed on the back of the electrolytic capacitor corresponding to the ESR typical reference table, the table is for reference only, please refer to the data published by the manufacturers.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e5. Calibration\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003eShort to 1, 2, 3 test points, press the \"boot \/ test\" button, the screen prompts whether to enter the calibration, in 2 seconds by \"power on \/ test\" button to confirm, enter the calibration.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003eAfter the screen prompts to disconnect 1, 2, 3 test points, continue after the break until the end of the prompt calibration.\u003c\/span\u003e\u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv\u003e\n\t\t\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003ePrecautions:\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\t\u003cdiv\u003e\n\t\t\u003cspan style=\"font-size: 14px;\"\u003eBe sure to discharge the instrument before testing the capacitor, otherwise it may damage the instrument.\u003c\/span\u003e\n\u003c\/div\u003e\n\t\u003cdiv\u003e\n\t\t\u003cspan style=\"font-size: 14px;\"\u003eWhen using the adapter, use an adapter with a DC 9V-12V (including 9V, 12V) voltage range.\u003c\/span\u003e\n\u003c\/div\u003e\n\t\u003cdiv\u003e\n\t\t\u003cspan style=\"font-size: 14px;\"\u003eThe instrument will not charge the battery, when the battery power is less than 6V, please replace the battery.\u003c\/span\u003e\n\u003c\/div\u003e\n\t\u003cdiv\u003e\n\t\t\u003cspan style=\"font-size: 14px;\"\u003eWhen the capacitor is discharged, it can be discharged without power on.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePacking Included:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\t \u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e1 x BSIDE ESR02PRO Digital Transistor Tester (\u003cstrong\u003eBattery is not included\u003c\/strong\u003e)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\t\u003cspan style=\"font-size:14px;\"\u003e1 x English User Manual \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eDetail Pictures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e","brand":"ontproduct","offers":[{"title":"Default Title","offer_id":49120544129249,"sku":"BG-1218985","price":241.72,"currency_code":"HKD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0853\/9317\/8849\/files\/fcdc5dba-814f-4a61-8e20-afbdaa1a57bd.jpg?v=1789396751","url":"https:\/\/ontproduct.com\/products\/esr02pro-digital-transistor-smd-components-tester-diode-triode-capacitance-inductance-meter","provider":"OntProduct","version":"1.0","type":"link"}