{"product_id":"dc-6-40v-battery-charger-discharger-board-integrated-voltmeter-undervoltage-overvoltage-protection-module-timing-charging-discharging-communication-function","title":"DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function","description":"\u003cdiv id=\"specification\"\u003e\u003c\/div\u003e\u003cdiv id=\"specification_end\"\u003e\u003c\/div\u003e\u003cp style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 14px;\"\u003e\u003cspan style=\"font-size: 18px; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 14px;\"\u003e\u003cspan style=\"font-size: 18px; font-weight: 700;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e1: Power supply voltage: DC6--40V, voltage detection range DC 0--60V, suitable for less than 60V of the various batteries, voltage measurement error ± 0.1V.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e2: charge and discharge time (OP) range: 0 - 999 minutes.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: 700;\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: 700;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. Battery charge and discharge intelligent control\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. You can set the charge and discharge time\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e3. With serial communication function, real-time monitoring of the working status of the relay through the serial port\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e4. Additional signal output, when the relay to meet the conditions, the output high, you can control other equipment\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e5. A key emergency stop function (STOP button), with reverse protection, reverse does not burn\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: 700;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: 700;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#666666\" face=\"OpenSans, Arial\"\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003cb\u003eOperating mode:\u003c\/b\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#666666\" face=\"OpenSans, Arial\"\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eVoltage upper limit: UL1, voltage lower limit nL1, the voltage upper limit is greater than the voltage lower limit (UL1\u0026gt; nL1)\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eU-1: Charging measurement: When the measured voltage is lower than the lower limit voltage, the relay pulls above; the upper limit voltage, the relay is disconnected.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eU-2: Charge measurement time control: set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage is higher than the upper limit voltage , The relay is disconnected.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eU-3: Discharge detection: When the measured voltage is lower than the lower limit voltage, the relay is off, above the upper limit voltage, the relay pulls.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eU-4: Discharge detection time control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage below the lower limit voltage , The relay is disconnected.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eU-5: Voltage in the range, the relay pull: when the measured voltage between the upper and lower limits, the relay pull, the other circumstances open.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eU-6: Voltage outside the interval, the relay pull: the measured voltage below the lower limit voltage or higher than the upper limit voltage, the relay pull, the other case the relay is off.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: 700;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: 700;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cfont color=\"#666666\" face=\"OpenSans, Arial\"\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003cb\u003eHow to set parameters\u003c\/b\u003e\u003c\/span\u003e\u003c\/font\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: bolder;\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: bolder;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. First, according to their needs, to determine the requirements of the work model;\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current mode of operation, the default U-1 mode, and then enter the main interface) press the SET button for 2 seconds and then release, enter the selection Mode interface, UP, DOWN button to select the mode to be set (U-1 ~ U-6);\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e3. After selecting the mode, assume that we have selected the U-1 mode and press the SET button to set the corresponding parameter. The parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), press UP, DOWN Key to increase or decrease, you can always press the key to quickly increase or decrease, press the SET button to set the current mode of the next parameter, the process above;\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e4. Set the parameters, and then press the SET button for 2 seconds to release, the current setting mode will flash, and then return to the main interface, set the parameters of success!\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e5. In the main interface, press the DOWN key to achieve voltage and time switching.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#666666\" face=\"OpenSans, Arial\"\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003cb\u003eMode selection interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/font\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: bolder;\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: bolder;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ePress the SET button for a long time to enter the mode selection interface, set the finished, a long time press the SET button and then release the exit mode selection interface, back to the main interface.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#666666\" face=\"OpenSans, Arial\"\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003cb\u003eAdditional features:\u003c\/b\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: bolder;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. Data upload: through the serial port to achieve data upload, interval 1s upload a voltage and run time, easy to post-data analysis;\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. Serial port settings parameters: You can set the mode and parameters through the serial port, more convenient;\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e3. An extra signal output, when the relay to meet the conditions, the output high, the other output low.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eSerial port control (TTL level communication)\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eCommunication standard:\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eThe baud rate is 115200 bps\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eData bits: 8\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eStop bit: 1\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eCheck digit: none\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eFlow control: none\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eSerial command:\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"U-1\": Operating mode (range U-1 to U-6)\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"000\": 0 - does not enable timing function, non-0 - enable timing function (range 001 to 999)\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"Dw02.9\": Set the lower limit voltage\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"Up10.1\": set the upper limit voltage (range 00.0V ~ 99.9V)\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"Get\": Get the current settings\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"On\": Allows the relay to turn on\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"Off\": Always turn off the relay\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"Start\": start uploading data\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"Stop\": stop uploading data\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eThe above command can be any combination of two, need to be separated by commas\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eSuch as: \"dw02.9, up10.1\" set the lower limit voltage 02.9V upper limit voltage 10.1V\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eUpload Status: Test Voltage + On Time + Status\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"00.0V, 00: 00: 00, OP  r  n\"\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e00.0V: Measured voltage\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e00:00:00: Relay on time\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eStatus: OP relay on, CL relay off\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: bolder;\"\u003e\u003c\/span\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003cfont color=\"#666666\" face=\"OpenSans, Arial\"\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003cb\u003eSTOP key function expansion:\u003c\/b\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp style=\"\"\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px; font-weight: bolder;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eRelay enable mode:\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. ON: OP conduction time, the relay allows conduction;\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. OFF: The relay is disabled and is always off;\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ePress the STOP button on the main interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is an emergency stop function, a key to disconnect the relay)\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eSleep mode:\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. O-d normal mode: digital tube is always open display;\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ePress and hold the STOP button for 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-weight: bolder; color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px;\"\u003ePackage include:\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-weight: bolder; color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 18px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: rgb(99, 99, 99); font-family: arial, helvetica, sans-serif; font-size: 14px;\"\u003e1×\u003c\/span\u003e\u003cfont color=\"#636363\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eBattery Charger Discharger Board\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e","brand":"LinkMejor","offers":[{"title":"Default Title","offer_id":49120791724257,"sku":"BG-1974136","price":8.99,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0853\/9317\/8849\/files\/79e62722-6296-4df6-8864-7cacbebf1c1e.jpg?v=1789396928","url":"https:\/\/ontproduct.com\/products\/dc-6-40v-battery-charger-discharger-board-integrated-voltmeter-undervoltage-overvoltage-protection-module-timing-charging-discharging-communication-function","provider":"IvySource","version":"1.0","type":"link"}